? Please refer to the help shown in the pop-ups ? * The calculation is made under your responsibility as designer of the safety function *
Attention You are currently not logged in to your account Comitronic BTI
You can calculate your assessment but you can not save the result (however, you can print).
A complete procedure for CCF prevention measures, covering sensors / actuators on the one hand, and the control logic on the other hand, is given for example in IEC 61508-6: 2000, Annex D. The measures provided in this regard are not all applicable to the.
NOTE : Dans la présente partie de l'ISO 13849 et conformément à la CEI 61508-6:2000, Annexe D, il convient que le facteur ß pour les systèmes redondants soit généralement inférieur ou égal à 2 %.
F.2 CCF impact estimation
Il convient que ce procédé quantitatif soit réalisé pour l'ensemble du système. Il convient de considérer chaque partie des éléments liés à la sécurité du système de commande.
Table F.1 lists the measures and contains the associated values, based on an expert assessment, which represent the contribution of each measure to reducing the common cause failures.
For each listed measure, only all-or-nothing results are to be declared. If a measure is only partially completed, the resulting score is zero.
Table F.2 shows a CCF quantification.
Table F.1 - Scoring process for CCF countermeasures
No.
CCF countermeasure
Score
1
Separation / Isolation
Physical separation between signal channels:
separation in wiring, piping,
sufficient clearance and creepage distances on the printed circuit boards.
(sur 15)
2
Diversity
Different design principles/technologies or physical principles are used, for example::
first electronic channel is programmable and second channel is wired
sort of initiation
pressure and temperature
Measuring the distance and pressure, for example::
digital and analogue,
Components from different manufacturers
Are the results of an analysis of failure modes and their effects taken into account in order to prevent common cause failures at the design stage? ?
(sur 5)
5
Skills / training
Are the maintenance specialist designers trained to understand the causes and consequences of common cause failures? ?
(sur 5)
6
Environment
6.1
Prevention of contamination and electromagnetic compatibility (EMC) CCF countermeasures in accordance with the relevant standards
Fluid systems: filtration of the medium under pressure, prevention of absorption of impurities, drainage of compressed air, for example in accordance with the component manufacturer's requirements regarding the purity of the medium under pressure,
Electrical systems: has the electromagnetic immunity of the system been verified, for example as specified in the applicable product standards? ?
For combined fluids and electrical systems, both aspects should be taken into consideration.
(sur 25)
6.2
Other influences
Have the requirements relating to immunity against all relevant environmental influences such as temperature, shock, vibration, and humidity been taken into account, for example as specified in the applicable standards? ?
(sur 10)
TOTAL
Table F.2 - CCF quantification
Total score
CCF countermeasuresa
65 or better
Satisfies the requirements
Less than 65
Method fails => choose additional measures
a Where technical provisions are not relevant, the points detailed in the right hand column can be considered as a complete calculation.