Position control on ATEX doors / casings
Sensor contactless technology, low simultaneity
ATEX Zone 2 and 22 category 3GD
No power
Atex safety
EN 60079-15
EN 61241-1
Machine Safety
Level of performance with AWAX26XXL-EEX3 controller | up to PL = e in accordance with EN ISO 13849-1 |
Cycle before dangerous failure | B10d = 62,500 |
Max. activation distance | 17 mm, 5 mm hysteresis |
Safety contacts/diagnostics | NO 2 x 50 mA/24V redundant 1xNF/50mA/24V redundant parallel |
Overcurrent | 500mA for 2s |
Shock resistance | 50 G. |
Vibrations | 30 G |
Detection encoding | mono-code |
Indicators | no |
Reset | automatic |
Total number of connectable sensors in series | 30 |
Attachment | 4 tamper-proof M4 screws (optional ref: BH4) |
Mounting position | 2 (double wall brackets) |
Material | PA6 |
Marking | pad printing + serial no. for traceability |
Electrical connection | 12m cable |
Water resistance | IP 67 |
Temperature |